dc.identifier.citationSantos, D., Carline, T., Richmond, R. & Abboud, R. (2003) A review of the effects of external pressure on skin blood flow, The Foot, vol. 13, , pp. 185-189,
dc.identifier.issn9582592
dc.identifier.urihttp://dx.doi.org/10.1016/j.foot.2003.08.003
dc.identifier.urihttps://eresearch.qmu.ac.uk/handle/20.500.12289/832
dc.description.abstractThe human foot is a complex mechanical structure consisting of bones, ligaments and joints. They act together to provide a robust system capable of absorbing and dissipating the intermitted pressure that is subjected to its plantar surface during walking to prevent soft tissue breakdown. Current studies suggest that plantar foot pressure may lead to soft tissue breakdown (e.g. neuropathic ulceration) and hence research has so far concentrated on investigating the mechanical effects of plantar foot pressure on the foot's integrity. This has been possible through the widely available pressure and force platforms as well as in-shoe pressure systems. However, to understand how plantar foot pressure causes soft tissue breakdown it is vital to investigate both the physiological-mechanical interactions between the skin and plantar foot pressure. This review suggests that with the current advances in technology, the physiological response of skin blood flow to mechanical plantar foot pressure should be investigated and correlated further, both during static and dynamic loading, by developing a new system capable of either measuring both variables simultaneously or by synchronising two systems in real time.
dc.format.extent185-189
dc.publisherElsevier
dc.relation.ispartofThe Foot
dc.subjectPlantar foot pressure
dc.subjectSkin blood flow
dc.subjectLaser Doppler fluxmeter
dc.titleA review of the effects of external pressure on skin blood flow
dc.typearticle
dcterms.accessRightsrestricted
dc.description.facultysch_pod
dc.description.referencetext[1] Yamaguchi K, Nanda RS, Kawata T. Effect of orthodontic forces on blood flow in human gingival. Angle Orthod 1991;61(3):193- 203. [2] Holloway GA, Daly CH, Kennedy D, Chimoskey J. Effects of external loading on human skin blood flow measured using 133Xe clearance. J Appl Physiol 1976;40(4):597-600. [3] Karlsmark T, Kristensen JK. A method for testing the effect of pressure-relieving materials in the prevention of pressure ulcers. Acta Dermatol Venereol (Stockholm) 1987;67:260-3. [4] Schubert V, Hraud J. The effects of pressure and shear on skin microcirculation in elderly stroke patients lying in supine or semi-recumbent positions. Age Ageing 1994;23(5):405-10. [5] Colin D, Saumet JL. Influence of external pressure on transcutaneous oxygen tension and laser Doppler flowmetry on sacral skin. Clin Physiol 1996;16(1):61-72. [6] Schubert V, Fagrell B. Local skin pressure and its effects on skin microcirculation as evaluated by laser-Doppler fluxmetry. Clin Physiol 1989;9:535-45. [7] Fromy B, Abraham P, Saumet J. Progressive calibrated pressure device to measure cutaneous blood flow changes to external pressure strain. Brain Res Brain Res Protoc 2000;5:198-203. [8] Abu-Own A, Sommerville K, Scurr JH, Coleridge-Smith PD. Effects of compression and type of bed surface on the microcirculation of the heel. Eur J Vasc Endovasc Surg 1995;9(3):327-34. [9] Proano E, M__tt_nen H, Perbeck L, Solders G, Turan I. The effect of weight-bearing pressure on the plantar circulation in diabetes mellitus. Diabetes Med 1992;9:722-9. [10] Perbeck L, Lund F, Svensson L, Thulin L. Fluorescein flowmetry: a method for measuring relative capillary blood flow in the intestine. Clin Physiol 1985;5(3):281-92. [11] Warden K, Nilsson G. Laser Doppler imaging of skin. In: Serup J, Jemec GBE, editors. Handbook of non-invasive methods and the skin. USA: CRC Press; 1995. p. 421-8 [chapter 17.4]. [12] Mayrovitz HN, Smith JR, Delgado M, Regan MB. Heel blood perfusion responses to pressure loading and unloading in women. Ostomy/ Wound Manage 1997;43(7):16-26. [13] Mayrovitz HN, Smith J. Heel-skin microvascular blood perfusion responses to sustained pressure loading and unloading. Microcirculation 1998;5:227-33. [14] Belcaro G, Nicolaides A. Laser Doppler fluxmetry: principles of technology and clinical applications. In: Serup J, Jemec GBE, editors. Handbook of non-invasive methods and the skin. USA: CRC Press; 1995. p. 405-10 [chapter 17.2]. [15] Bircher A, DeBoer EM, Agner T, Wahlberg JE, Serup J. Guidelines for measurement of cutaneous blood flow by laser Doppler flowmetry. A report from the Standardisation Group of the European Society of Contact Dermatitis. Contact Dermatitis 1994;30(2):65-72. [16] Cobb J, Claremont D. An in-shoe laser Doppler sensor for assessing plantar blood flow in the diabetic foot. Med Eng Phys 2001;23:417- 25. [17] Santos D, Carline T, Richmond R, Abboud RJ. A modular device to measure the effects of plantar foot pressure on the microcirculation of the heel. The Foot 2003;13:30-8. [18] Abu-Own A, Cheatle T, Scurr JH, Coleridge-Smith PD. Effects of intermittent pneumatic compression of the foot on the microcirculatory function in arterial disease. Eur J Vasc Surg 1993;7(5):488-92. [19] Abu-Own A, Shami SK, Chittenden SJ, Farrah J, Scurr JH, Coleridge-Smith PD. Microangiopathy of the skin and the effect of leg compression in patients with chronic venous insufficiency. J Vasc Surg 1994;19(6):1074-83. [20] Meinders MJ, DeLange A, Netten PM, Wollesheim H. Microcirculation in the footsole as a function of mechanical pressure. Clin Biomech 1996;11(7):410-7.
dc.description.volume13
dc.identifier.doihttp://doi:10.1016/j.foot.2003.08.003
dc.description.ispublishedpub
dc.description.eprintid832
rioxxterms.typearticle
qmu.authorCarline, Tom
qmu.authorSantos, Derek
dc.description.statuspub
dc.description.number4


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record