Repository logo
 

Validation of the activPAL3 activity monitor in people moderately affected by Multiple Sclerosis

dc.contributor.authorCoulter, Elaine H.
dc.contributor.authorMiller, Linda
dc.contributor.authorMcCorkell, Sara
dc.contributor.authorMcGuire, Caroline
dc.contributor.authorAlgie, Kimberley
dc.contributor.authorFreeman, Jenny
dc.contributor.authorWeller, Belinda
dc.contributor.authorMattison, Paul
dc.contributor.authorMcConnachie, Alex
dc.contributor.authorWu, Olivia
dc.contributor.authorPaul, Lorna
dc.date.accessioned2018-06-29T21:45:45Z
dc.date.available2018-06-29T21:45:45Z
dc.date.issued2017-04-10
dc.description.abstractBackground: Walking is the primary form of physical activity performed by people with Multiple Sclerosis (MS), therefore it is important to ensure the validity of tools employed to measure walking activity. The aim of this study was to assess the criterion validity of the activPAL3 activity monitor during overground walking in people with MS. Methods: Validity of the activPAL3 accelerometer was compared to video observation in 20 people moderately affected by MS. Participants walked 20-30m twice along a straight quiet corridor at a comfortable speed. Results: Inter-rater reliability of video observations was excellent (all intraclass correlations > 0.99). The mean difference (activPAL3- mean of raters) was -4.70 ± 9.09, -4.55 s ± 10.76 and 1.11 s ± 1.11 for steps taken, walking duration and upright duration respectively. These differences represented 8.7, 10.0 and 1.8% of the mean for each measure respectively. The activPAL3 tended to underestimate steps taken and walking duration in those who walked at cadences of ≤ 38 steps/minute by 60% and 47% respectively. Discussion: The activPAL3 is valid for measuring walking activity in people moderately affected by MS. It is accurate for upright duration regardless of cadence. In participants with slow walking cadences, outcomes of steps taken and walking duration should be interpreted with caution.
dc.description.eprintid4691
dc.description.facultysch_phy
dc.description.ispublishedpub
dc.description.statuspub
dc.identifierER4691
dc.identifier.citationCoulter, E.H., Miller, L., McCorkell, S., McGuire, C., Algie, K., Freeman, J., Weller, B., Mattison, P.G., McConnachie, A., Wu, O. and Paul, L. (2017) ‘Validity of the activPAL3 activity monitor in people moderately affected by Multiple Sclerosis’, Medical Engineering & Physics, 45, pp. 78–82. Available at: https://doi.org/10.1016/j.medengphy.2017.03.008.
dc.identifier.doihttp://10.1016/j.medengphy.2017.03.008
dc.identifier.issn1350-4533, ESSN: 1873-4030
dc.identifier.urihttp://doi.org/10.1016/j.medengphy.2017.03.008
dc.identifier.urihttps://eresearch.qmu.ac.uk/handle/20.500.12289/4691
dc.publisherElsevier
dc.relation.ispartofMedical Engineering and Physics
dc.titleValidation of the activPAL3 activity monitor in people moderately affected by Multiple Sclerosis
dc.typearticle
dcterms.accessRightsrestricted
qmu.authorCoulter, Elaine H.
qmu.centreCentre for Health, Activity and Rehabilitation Research
refterms.dateAccepted2017-03-26
refterms.dateFCA2018-04-10
refterms.dateFCD2017-03-27
rioxxterms.typearticle

Files

Original bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
eResearch%204691%20aam.pdf
Size:
393.04 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
eResearch%204691.pdf
Size:
340.81 KB
Format:
Adobe Portable Document Format

Collections