Repository logo
 

Using Lean Six Sigma to redesign the supply chain to the operating room department of a private hospital to reduce associated costs and release nursing time to care

dc.contributor.authorO’Mahony, Lisa
dc.contributor.authorMcCarthy, Kerrie
dc.contributor.authorO’Donoghue, Josephine
dc.contributor.authorTeeling, Sean Paul
dc.contributor.authorWard, Marie
dc.contributor.authorMcNamara, Martin
dc.date.accessioned2021-10-25T08:44:51Z
dc.date.available2021-10-25T08:44:51Z
dc.date.issued2021-10-20
dc.date.updated2021-10-21T23:05:21Z
dc.descriptionFrom MDPI via Jisc Publications Router
dc.descriptionHistory: accepted 2021-10-18, pub-electronic 2021-10-20
dc.descriptionPublication status: Published
dc.descriptionSeán Paul Teeling - ORCID: 0000-0002-4102-7280 https://orcid.org/0000-0002-4102-7280
dc.description.abstractContinuity of the supply chain is an integral element in the safe and timely delivery of health services. Lean Six Sigma (LSS), a continuous improvement approach, aims to drive efficiencies and standardisation in processes, and while well established in the manufacturing and supply chain industries, also has relevance in healthcare supply chain management. This study outlines the application of LSS tools and techniques within the supply chain of an Operating Room (OR) setting in a private hospital in Dublin, Ireland. A pre-/post-intervention design was employed following the Define, Measure, Analyse, Improve, Control (DMAIC) framework and applying LSS methodology to redesign the current process for stock management both within the OR storage area and within a pilot OR suite, through collaborative, inclusive, and participatory engagement with staff. A set of improvements were implemented to standardise and streamline the stock management in both areas. The main outcomes from the improvements implemented were an overall reduction in the value of stock held within the operating theatre by 17.7%, a reduction in the value of stock going out of date by 91.7%, and a reduction in the time spent by clinical staff preparing stock required for procedures by 45%, all demonstrating the effectiveness of LSS in healthcare supply chain management.
dc.description.ispublishedpub
dc.description.number21
dc.description.statuspub
dc.description.volume18
dc.identifierdoi: 10.3390/ijerph182111011
dc.identifierhttps://eresearch.qmu.ac.uk/bitstream/handle/20.500.12289/11544/11544.pdf
dc.identifierhttps://eresearch.qmu.ac.uk/bitstream/handle/20.500.12289/11544/11544.pdf
dc.identifier.citationO’Mahony, L., McCarthy, K., O’Donoghue, J., Teeling, S.P., Ward, M. and McNamara, M. (2021) 'Using Lean Six Sigma to redesign the supply chain to the operating room department of a private hospital to reduce associated costs and release nursing time to care', International Journal of Environmental Research and Public Health, 18(21), article no. 11011.
dc.identifier.issn1660-4601
dc.identifier.urihttps://eresearch.qmu.ac.uk/handle/20.500.12289/11544
dc.identifier.urihttps://doi.org/10.3390/ijerph182111011
dc.languageen
dc.publisherMDPI
dc.relation.ispartofInternational Journal of Environmental Research and Public Health
dc.rightsLicence for this article: https://creativecommons.org/licenses/by/4.0/
dc.rights.licenseCreative Commons Attribution License
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceeissn: 1660-4601
dc.subjectSupply Chain Management
dc.subjectHealthcare
dc.subjectLean Six Sigma
dc.subject5S
dc.subjectStandardisation
dc.subjectStock Management
dc.subjectNursing Time
dc.titleUsing Lean Six Sigma to redesign the supply chain to the operating room department of a private hospital to reduce associated costs and release nursing time to care
dc.typeArticle
dcterms.accessRightspublic
dcterms.dateAccepted2021-10-18
qmu.authorTeeling, Sean Paul
qmu.centreCentre for Person-centred Practice Research
refterms.dateDeposit2021-10-25
refterms.dateFCD2021-10-25

Files

Original bundle

Now showing 1 - 2 of 2
Thumbnail Image
Name:
11544.pdf
Size:
1.03 MB
Format:
Adobe Portable Document Format
Description:
Published Version
No Thumbnail Available
Name:
11544.xml
Size:
8.95 KB
Format:
Extensible Markup Language
Description:
XML

Collections