Repeatability and Reproducibility of the F-Scan System in Healthy Children

dc.contributor.authorCoda, Andrea
dc.contributor.authorSantos, Derek
dc.date.accessioned2018-06-29T21:48:23Z
dc.date.available2018-06-29T21:48:23Z
dc.date.issued2015-11-10
dc.description.abstractThis study investigated the repeatability and reproducibility of the F-scan system with regards to Peak Pressure Values (PP) and Pressure Time Integral (PTI) in healthy children, ranging between 5 to 18 years of age. Participants took part in two non-invasive clinical assessments, at baseline and one week later. Standardized footwear was supplied and each child was fitted with the equivalent F-scan insole size. A total of 3 trials of 7 meters distance each were conducted. Plantar pressure analysis was carried out using a novel approach of masking the recordings into 10 different areas; both peak pressure (PP) and pressure time integrals (PTI) values were investigated. The PP and PTI were investigated for the left, right and both feet analysed together. Interclass Correlation Coefficient (ICC) test was adopted for statistical analysis. Overall, 30 healthy children were recruited and 60 appointments were completed; 53.3% (n = 16) were female, mean age was 13.3 years (SD = 4.5). Results highlighted that overall the ICC for repeatability was > 0.75 for 95.8% (no = 115) and between 0.5 and 0.75 for 4.2% (no = 5); the ICC for reproducibility was > 0.75 for 85% (no = 51), and between 0.5 and 0.75 for 15% (no = 9). In conclusion, the F-Scan system can be utilised to record repeatable and reproducible data in paediatric gait analysis.
dc.description.eprintid4215
dc.description.facultysch_pod
dc.description.ispublishedpub
dc.description.number1
dc.description.referencetext1. Ahroni JH, Boyko EJ, Forsberg R. Reliability of F-scan in-shoe measurements of plantar pressure. Foot Ankle Int. 1998;19(10):668-73. 2. Chen B, Bates B. Comparison of F-Scan in-sole and AMTI forceplate system in measuring vertical ground reaction force during gait. Physiotherapy Theory & Practice. 2000;16(1):43-53. doi:10.1080/095939800307601. 3. Joanne S Paton, Elizabeth A Stenhouse, Graham Bruce, Daniel Zahra, and Ray B Jones. A comparison of customised and prefabricated insoles to reduce risk factors for neuropathic diabetic foot ulceration: a participantblinded randomised controlled trial. J Foot Ankle Res. 2012; 5: 31. doi: 10.1186/1757-1146-5-31. 4. Luo ZP, Berglund LJ, An KN. Validation of F-Scan pressure sensor system: a technical note. J Rehabil Res Dev. 1998;35(2):186-91. 5. Randolph AL, Nelson M, Akkapeddi S, Levin A, Alexandrescu R. Reliability of measurements of pressures applied on the foot during walking by a computerized insole sensor system. Arch Phys Med Rehabil. 2000;81(5):573-8. 6. Quesada P, Rash G, Jarboe N. Assessment of pedar and F-Scan revisited. Clin Biomech (Bristol, Avon). 1997;12(3):S15. 7. Tekscan. F-scan user manual Tekscan; 2010. 8. SIGN. Management of Obesity, a national clinical guideline. Scottish Intercollegiate Guidelines Network, Part of NHS Quality Improvement Scotland. 2010. 9. Bolton W. Instrumentation and measurement, 3rd ed. Newnes B-H, editor. 2000. p. 3-40. 10. Bircher A, DeBoer E, Agner T, Wahlberg J, Serup J. Guidelines for Measurement of cutaneous blood flow by laser Doppler flowmetry. Contact Dermatitis. 1994;30(2):65-72. 11. Portney LG, Watkins MP. Foundations of Clinical Research: Applications to Practice. 2nd ed. Prentice Hall Health, Upper Saddle River; 2000. 12. Fleiss JL. The Design and Analysis of Clinical Experiments. 1st Ed. New York: Wyley; 1986. 13. Li Lu M, Nawar S. Reliability analysis: Calculate and Compare Intraclass Correlation Coefficients (ICC) in SAS. Epidemiology DoBa, editor. Hyattsville: The MedStar Research Institute; 2007. 14. Bland JM, Altman DG. Measurement error and correlation coefficients. BMJ. 1996;313(7048):41-2. 15. Menz H. Two feet, or one person? Problems associated with statistical analysis of paired data in foot and ankle medicine. The Foot. 2004;14(1):2-5. 16. Brostrom E, Haglund-Akerlind Y, Hagelberg S, Cresswell AG. Gait in children with juvenile chronic arthritis. Timing and force parameters. Scand J Rheumatol. 2002;31(6):317-23. 17. Dixon SJ, McNally K. Influence of orthotic devices prescribed using pressure data on lower extremity kinematics and pressures beneath the shoe during running. Clin Biomech (Bristol, Avon). 2008;23(5):593-600. doi: 10.1016/j.clinbiomech.2008.01.015. 18. Fairburn PS, Panagamuwa B, Falkonakis A, Osborne S, Palmer R, Johnson B, et al. The use of multidisciplinary assessment and scientific measurement in advanced juvenile idiopathic arthritis can categorise gait deviations to guide treatment. Arch Dis Child. 2002;87(2):160-5. 19. Hadfield MH, Snyder JW, Liacouras PC, Owen JR, Wayne JS, Adelaar RS. Effects of medializing calcaneal osteotomy on Achilles tendon lengthening and plantar foot pressures. Foot Ankle Int. 2003;24(7):523- 9. 20. Hendry GJ, Turner DE, McColl J, Lorgelly PK, Sturrock RD, Watt GF, et al. Protocol for the Foot in Juvenile Idiopathic Arthritis trial (FiJIA): a randomised controlled trial of an integrated foot care programme for foot problems in JIA. J Foot Ankle Res. 2009;2:21. doi: 10.1186/1757- 1146-2-21. 21. Gurney JK, Kersting UG, Rosenbaum D. Between-day reliability of repeated plantar pressure distribution measurements in a normal population. Gait Posture. 2008;27(4):706-9. 22. Castro M, Abreu S, Sousa H, Machado L, Santos R, Vilas-Boas JP. Ground reaction forces and plantar pressure distribution during occasional loaded gait. Appl Ergon. 2013;44(3):503-9. doi: 10.1016/j. apergo.2012.10.016. 23. Coda A, Carline T, Santos D. Repeatability and reproducibility of the Tekscan HR-Walkway system in healthy children. Foot (Edinb). 2014;24(2):49-55. doi: 10.1016/j.foot.2014.02.004.
dc.description.statuspub
dc.description.volume1
dc.identifierER4215
dc.identifier.citationCoda, A. and Santos, D. (2015) ‘Repeatability and reproducibility of the f-scan system in healthy children’, Journal of Orthopedics, Rheumatology and sports Medicine. Available at: https://doi.org/10.19104/jorm.2015.104.
dc.identifier.doihttp://10.19104/jorm.2015.104
dc.identifier.urihttps://eresearch.qmu.ac.uk/handle/20.500.12289/4215
dc.publisherELYNS Publications Group
dc.relation.ispartofJournal of Orthopedics, Rheumatology and Sports Medicine
dc.subjectChildren
dc.subjectPlantar Pressure
dc.subjectF-Scan
dc.subjectTekscan
dc.subjectRepeatability
dc.subjectReproducibility
dc.titleRepeatability and Reproducibility of the F-Scan System in Healthy Children
dc.typearticle
dcterms.accessRightspublic
qmu.authorSantos, Derek
qmu.authorCoda, Andrea
qmu.centreCentre for Health, Activity and Rehabilitation Research
rioxxterms.typearticle

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
4215.pdf
Size:
734.83 KB
Format:
Adobe Portable Document Format
Description:
Open Access

Collections