Repository logo
 

Perometry limb volume measurement: Protocol development and reliability

dc.contributor.authorBulley, Catherine
dc.contributor.authorCoutts, Fiona
dc.contributor.authorTan, Chee-Wee
dc.date.accessioned2018-06-29T21:45:13Z
dc.date.available2018-06-29T21:45:13Z
dc.date.issued2013-12
dc.description.abstractAims: Perometry measurement of limb volume involves non-invasive optoelectronic scanning and is increasingly used due to its practicality and increasing evidence for its validity. This study aimed to develop a standardized protocol for the measurement of upper and lower limb volume using a vertical perometer (400T) and test its reliability. Methodology: Multiple pilot studies were conducted in a laboratory-based setting to investigate specific procedural questions and develop the final standardized protocol. This included elements such as standardization of the proportion of limb being measured, and of limb positioning within the perometer frame. The standardized protocol was tested for inter-and intra-rater reliability in two raters, on two separate test occasions, 24-48 h apart. The study included 30 volunteers with no known clinical conditions (n = 23 women, seven men; mean age 23). Major findings: High intra-class correlation coefficient (ICC) values resulted for intra-rater and inter-rater reliability in the upper and lower limbs (0.953-0.989). Limits of agreement analysis demonstrated less positive results, however. Principal conclusion: The results provide support for the use of this protocol to increase standardization and comparability of measurement in clinical and research contexts. Further investigation in different clinical populations is required. 2013 Informa Healthcare.
dc.description.eprintid3334
dc.description.facultysch_phy
dc.description.ispublishedpub
dc.description.number4
dc.description.statuspub
dc.description.volume15
dc.format.extent193-200
dc.identifierER3334
dc.identifier.citationBulley, C., Coutts, F. and Tan, C.W. (2013) ‘Perometry limb volume measurement: protocol development and reliability’, European Journal of Physiotherapy, 15(4), pp. 193–200. Available at: https://doi.org/10.3109/21679169.2013.831482.
dc.identifier.doihttp://10.3109/21679169.2013.831482
dc.identifier.issn21679169
dc.identifier.urihttp://dx.doi.org/10.3109/21679169.2013.831482
dc.identifier.urihttps://eresearch.qmu.ac.uk/handle/20.500.12289/3334
dc.relation.ispartofEuropean Journal of Physiotherapy
dc.titlePerometry limb volume measurement: Protocol development and reliability
dc.typearticle
dcterms.accessRightsnone
qmu.authorTan, Chee-Wee
qmu.authorBulley, Catherine
qmu.authorCoutts, Fiona
rioxxterms.typearticle

Files

Collections